These listings are short summaries to serve as a.
1 hour roof ceiling assembly.
Urb concealed grid system and tile.
With 1 2 wood structural panels with exterior glue applied at right angles to top of joist or top chord of trusses with 8d nails.
12 x 24 2 x 4 8 w10 x 25 beam floor units and beam support 3 hr.
3 4 fr 83 12 x 12 z runners fluorescent type none 2 1 2 concrete.
Wood joists wood i joists floor trusses and flat or pitched roof trusses spaced a maximum 24 o c.
One hour roof ceiling assembly.
Our range of drawings can help pros plan projects more effectively by utilizing designs for a fire rated ceiling assembly.
Fc4 fc9 1 hour wood rafter floor assembly.
Fc1 fc2 fc3 fc6 fc7 fc8 2 hour floor ceiling assembly.
276 fire rated ceiling assemblies suspension ceiling designs floor ceiling designs a003 3 hr.
Type x gypsum wallboard 4 ft.
Here you can find drawings for our ul fire rated floor assemblies and ul fire rated ceiling assemblies.
6 usg fire resistant assemblies test certiļ¬cation test conditions and fire and sound tested assemblies listed in this selector are based on characteristics properties and performance certificationof materials and systems obtained under controlled test conditions as set forth in the appropriate astm standard in effect at the time of test.
Sheathing 5 8 in.
Framing nominal 2x4 wood studs spaced 16 in.
Fw1 fw2 fw3 fw4 fw5 fw6 fw7 fw8 fw9 fw12 2 hour wood rafter floor assembly.
Is this possible without using channels and what ul number would i use.
Concrete with cellular steel 3 hr.
Wood and gypsum floor ceiling and wood roof assemblies 1 hour floor ceiling assembly.
1 2 12 7 mm toughrock fireguard c or 1 2 12 7 mm densarmor plus fireguard c gypsum panel applied perpendicular to resilient channels 24 610 mm o c.
Fire rated wood frame wall and floor ceiling assemblies 5 ws4 1 1 one hour fire resistive wood frame wall assembly 2x4 wood stud wall 100 design load astm e 119 nfpa 251.
Gypsum panel end joints located midway between continuous channels and attached to additional pieces of channels 54 1372 mm long with screws 12 305 mm o c.
I would like to apply the drywall directly to the bottom of the truss and also have insulation for sound control.
I am looking for a 1 hour roof ceiling assembly for wood truss construction.
With 1 25 mm type s drywall screws 12 305 mm o c.
O c double top plates single bottom plate.
Fw10 fw11 1 hour roof assembly.
2 1 3 4 2.
Ibctable 721 3 item 21 1 1 describes a single prescriptive 1 hour rated floor or roof assembly that includes wood trusses.
Screw fastened perpendicular to lower chord of wood trusses of 2 x 4 38 mm x 89 mm.